Steam Generator Iron Water Pump Replacement.

 

Before buying make sure there is no blockage in the iron.

Steam Generator Iron Feed Water Pump Replacement.

This feed pump is suitable to Morphy Richards, Steamworks, AVR, and Kenwood steam generator irons.

It is a simple job to replace the feed pump.

When pushing the trigger and no steam 100% pump gone and need replacement.

The possible fault is mechanical and electrical.

If a mechanical fault occurs, the pump will run as usual and make the same noise but no steam or very little steam.

Pump feed very little water to the boiler and boiler makes very little steam.

You can test it your pump by disconnecting the hose from the water tank and put this end in the glass of water and let it run and see if sucking water from the glass.

This can happen as the pump doesn't like to "dry run" when cartridge in water tank left to dry.

Time from start to until can hear start feed water to the boiler is called "dry run".

It is longer and more often, the pump will stop work sooner.

If an electrical fault occurred pump is dead and not working at all.

An electrical fault is occurred by overheating of the pump.

The pump has a thermal fuse.

Is recommended to 1 min off after 2 mins continuous work to let the pump cool down.

The pump can make a noise or be dead but if no steam not working.

 

If you need advice regarding repair faulty steam generator iron to click like and contact us.

The description is based on experience with faulty steam generator irons.

Before you purchase the pump I suggest to open the base and take a look if other components are fine as may have water hose damaged or steam hose blocked.

The steam hose is likely to block in the elbow feeding the steam to the soleplate you need to open the iron.

To open the iron starting from the back unscrew one or two screws, then using a flat screwdriver lift the top of the handle starting from the back.

There is screw close to the soleplate tip when you remove the top of the handle and two screws at the back.

 

Pump technical details:

Voltage:230V/50Hz

Power: 19 W

Max pressure: 2-4 Bar

Max. flow rate 110+/-15cc/min.

Steam generator iron manufacturer flow rate is 90 cc/min.

How to change the water pump in Morphy Richards steam generator iron guide. 

 